A.
|
PLAN
SUBMITTALS
|
|
|
|
|
|
|
1.
|
GENERAL:
|
|
|
|
To
assist the Lessee in organizing time schedules and planned work
efforts by the Lessee's architectural and engineering team, the
following guidelines for submittals have been developed. Prior
to preparing designs, calculations and specifications, the Lessee
and the Lessee's architectural and engineering team should be thoroughly
familiar with the development criteria presented in this packet,
all local building codes, provisions of the Lessee's Lease Agreement,
development plans for the center and as-built conditions of the
project.
|
|
|
|
|
|
|
2.
|
CONCEPTUAL
DESIGN SUBMITTAL:
|
|
|
|
Within
thirty (30) days after Lessee's receipt of a fully executed copy
of the Lease Agreement (unless otherwise noted in the Lessee's Agreement)
and before Design Review Submittal to the City, Lessee must submit
to the Developer for its approval two (2) copies of preliminary
plans for the site and building. The Conceptual Design Submittal
shall include:
|
|
|
|
a)
|
Overall
site plan showing building footprint, parking lot layout complete
with points of ingress and egress, loading area (if provided), trash
enclosure, and hardscape and landscape areas. Ground signs
should be clearly indicated, if allowed.
|
|
|
|
b)
|
Preliminary
building floor plan, with overall dimensions.
|
|
|
|
c)
|
Conceptual
colored exterior elevations for all building sides, including the
indication of materials to be used and proposed building signage
(with sign sizes and types noted).
|
|
|
|
d)
|
Material
and color selection board.
|
|
|
|
|
|
|
3.
|
SITE
DEVELOPMENT PLAN SUBMITTAL:
|
|
|
|
Within
thirty (30) days after the Developer's approval of the Lessee's
Conceptual Design Submittal (unless otherwise noted in the Lessee's
agreement), and before Design Review Submittal to the City, Lessee
agrees to submit to the Developer for its approval two (2) copies
of the preliminary plans and specifications for the proposed site
development and building. Developer will submit this plan
to the Desert Ridge Design Review Committee for approval on behalf
of Lessee. The Site Improvement Plans must be at a minimum
1" ‚ 30' scale and shall include:
|
|
|
|
a)
|
Overall
Site Plan dimensioned to show building location, parking lot layout
and all landscape and hardscape areas.
|
|
|
|
b)
|
Overall
Landscape Plan with planting legend and tree sizes.
|
|
|
|
c)
|
Grading
Plan.
|
|
|
|
d)
|
Preliminary
Site Lighting Plan with fixture selections and site photometrics,
if applicable.
|
|
|
|
e)
|
Building
Floor Plan with overall dimensions. Plan to be 1/8" scale.
|
|
|
|
f)
|
Exterior
Elevations ‚ all building sides with signage shown and roof line
dashed with roof mechanical equipment shown dashed. Elevations
to be 1/8" scale. All colors and materials to be noted.
|
|
|
|
g)
|
Refuse
enclosure elevations.
|
|
|
|
|
|
|
4.
|
FINAL
PLAN SUBMITTAL:
|
|
|
|
Within
sixty (60) days after the Developer's approval of the Lessee's Site
Improvement Plan submittal (unless otherwise noted in the Lessee's
agreement), and before Plans Review submittal to the City, the Lessee
agrees to submit to the Developer two (2) blue-line copies of substantially
complete plans and written specifications for the work along with
the site and building signage locations and designs.
|
|
|
|
|
|
|
|
The
Final Plan Submittal plans must be in substantial conformance with
the approved Conceptual Design and Site Improvement Plan submittals.
|
|
|
|
|
|
|
|
It
is the Developer's intent that the final plan submittal be based
on approximately 80% complete working drawings to allow the Lessee
and the Lessee's architect and engineer time to make Developer-required
corrections prior to the completion of the plans and submittal of
documents for plan check. Once corrections have been made
and the Lessee has secured all building permits, a record set of
approved plans and specifications shall be forwarded to the Developer.
|
|
|
|
|
|
B.
|
UTILITY
DIRECTORY
|
|
|
|
|
|
|
GAS:
|
|
|
|
Southwest
Gas Company
|
|
|
|
10851
N. Black Canyon Highway
|
|
|
|
P.O.
Box 52075
|
|
|
|
Phoenix,
Arizona 85072
|
|
|
|
Phone:
(602) 395-4164
|
|
|
|
FAX:
(602) 395-4040
|
|
|
|
Contact:
Sam McConnell, Sr. Account Representative
|
|
|
|
|
|
|
ELECTRIC:
|
|
|
|
Arizona
Public Service
|
|
|
|
4625
E. Bell Road
|
|
|
|
P.O.
Box 53933 ‚ MS 4030
|
|
|
|
Phoenix,
Arizona 85072
|
|
|
|
Phone:
(602) 493-4430
|
|
|
|
FAX:
(602) 493-4400
|
|
|
|
Contact:
Glover Rawls
|
|
|
|
|
|
|
TELEPHONE:
|
|
|
|
Qwest
Communications
|
|
|
|
1022
N. 25th Avenue, Suite 100
|
|
|
|
Phoenix,
Arizona 85021
|
|
|
|
Phone:
(602) 630-5485
|
|
|
|
Contact:
Dan Szolowicz, Engineer
|
|
|
|
|
|
|
CABLE:
|
|
|
|
COX
Communications
|
|
|
|
17602
N. Black Canyon Highway
|
|
|
|
Phoenix,
Arizona 85053
|
|
|
|
Phone:
(623) 322-7851
|
|
|
|
FAX:
(623) 322-7424
|
|
|
|
Contact:
Randy Rolland
|
|
|
|
|